WO-2026-01449
Work order
- Priority
- P3
- Type
- Corrective
- Status
- Verified
- Created
- 2026-10-22 11:00 UTC
- Planned visit
- 2026-10-24 08:00 UTC
- Response due
- 2026-10-25 11:00 UTC
- On site
- 2026-10-24 08:00 UTC
- Completed
- 2026-10-24 09:25 UTC
- Verified
- 2026-10-24 09:45 UTC
- Cancellation reason
- –
- Notes
- Presence sensor replaced.
Visits site (VisitsSite) 1
- Triangeln Parkering · Malmö
Concerns charge points (ConcernsChargePoint) 1
- SE-MMA-001-01 · SV-Fast 75
Answers faults (AnswersFault) 1
- FLT-26-0557 · EVCommunicationError · Closed
Service visits (HasServiceVisit) 1
- 2026-10-24 08:00 UTC · Connector status stuck on Occupied with no vehicle present. Sensor wiring corroded.
Part fittings (UsesPartFitting) 1
- 2026-10-24 09:00 UTC · Fault · 1 pcs