WO-2026-01431
Work order
- Priority
- P1
- Type
- Corrective
- Status
- Verified
- Created
- 2026-10-20 10:30 UTC
- Planned visit
- 2026-10-20 14:00 UTC
- Response due
- 2026-10-20 14:30 UTC
- On site
- 2026-10-20 14:00 UTC
- Completed
- 2026-10-20 17:30 UTC
- Verified
- 2026-10-20 17:50 UTC
- Cancellation reason
- –
- Notes
- Main contactor and control board replaced.
Visits site (VisitsSite) 1
- Nya Ullevi Besökspark · Göteborg
Concerns charge points (ConcernsChargePoint) 1
- SE-GBG-006-01 · CC-Ultra 200
Answers faults (AnswersFault) 1
- FLT-26-0544 · PowerSwitchFailure · Closed
Service visits (HasServiceVisit) 1
- 2026-10-20 14:00 UTC · Ultra-fast charger failing to start sessions; contactor welded shut and error E-217 logged.
Part fittings (UsesPartFitting) 2
- 2026-10-20 16:30 UTC · Fault · 1 pcs
- 2026-10-20 16:50 UTC · Fault · 1 pcs