WO-2026-01389
Work order
- Priority
- P3
- Type
- Corrective
- Status
- Verified
- Created
- 2026-10-10 08:00 UTC
- Planned visit
- 2026-10-12 09:00 UTC
- Response due
- 2026-10-13 08:00 UTC
- On site
- 2026-10-12 09:10 UTC
- Completed
- 2026-10-12 10:20 UTC
- Verified
- 2026-10-12 10:45 UTC
- Cancellation reason
- –
- Notes
- Socket outlet on connector 2 replaced.
Visits site (VisitsSite) 1
- Vasastan Odenplan · Stockholm
Concerns charge points (ConcernsChargePoint) 1
- SE-STO-005-01 · NV-Wallbox 22
Answers faults (AnswersFault) 1
- FLT-26-0518 · GroundFailure · Closed
Service visits (HasServiceVisit) 1
- 2026-10-12 09:10 UTC · Residual current device tripping repeatedly in wet weather. Earth leakage found at connector 2 socket.
Part fittings (UsesPartFitting) 1
- 2026-10-12 10:00 UTC · Fault · 1 pcs