WO-2026-01291
Work order
- Priority
- P1
- Type
- Corrective
- Status
- Verified
- Created
- 2026-09-21 08:00 UTC
- Planned visit
- 2026-09-21 13:00 UTC
- Response due
- 2026-09-21 12:00 UTC
- On site
- 2026-09-21 13:20 UTC
- Completed
- 2026-09-21 16:45 UTC
- Verified
- 2026-09-21 17:10 UTC
- Cancellation reason
- –
- Notes
- Response target missed by 80 minutes, technician was tied up on another call-out.
Visits site (VisitsSite) 1
- Hyllie Handelsplats · Malmö
Concerns charge points (ConcernsChargePoint) 1
- SE-MMA-007-01 · CC-Rapid 150
Answers faults (AnswersFault) 1
- FLT-26-0455 · HighTemperature · Closed
Service visits (HasServiceVisit) 1
- 2026-09-21 13:20 UTC · DC charger derating to 50 kW. Power module 2 reporting overtemperature and fan failure.
Part fittings (UsesPartFitting) 2
- 2026-09-21 16:00 UTC · Fault · 1 pcs
- 2026-09-21 16:15 UTC · Fault · 1 pcs