NordCharge field crew

Service visit 2026-10-20 14:00 UTC

Service visit
Arrived
2026-10-20 14:00 UTC
Departed
2026-10-20 17:30 UTC
Findings
Ultra-fast charger failing to start sessions; contactor welded shut and error E-217 logged.
Actions taken
Replaced main contactor and control board, cleared fault, commissioned test session at 280 kW.
Warranty claim
WC-2026-04866

Made for work order (ForWorkOrder) 1

Part fittings used (UsedInServiceVisit) 2

Add a link